Model:SB-120PY
Use:This is a bridge box capable of measurement in post-yield (large strain) range.
This is a bridge box capable of measurement in post-yield (large strain) range. Bridge method is chosen by the setting of switches, and measurement range between normal and large strain is also set by a switch. When setting the large strain measurement, sensitivity is decreased to 1/10 of the normal sensitivity. Using a dynamic strainmeter having measurement range of 20000 x 10-6 strain for example, it is possible to measure up to 200000 x 10-6 strain. The large strain measurement is possible in quarter bridge method. The number of channels is available in 2, 4, 6, 8 and 10.
Type |
SB-120PY-2/4/6/8/10 |
Number of channels |
SB-120PY-2
: 2 channel |
Bridge
method |
Quarter
bridge 2-wire (Quarter bridge with short-circuit between B and C),
Quarter bridge 3-wire 120 Ω |
Bridge
method |
Quarter bridge 2-wire (Quarter bridge with short-circuit between B and C), Quarter bridge 3-wire 120 Ω |
Connection |
Screwing or soldering |
Dimensions |
SB-120PY-2:
55(W)×35(H)×100(D)mm |
Weight |
SB-120PY-2:
0.4kg |
Option |
CR-612 attached (the same quantity as the number of channels) |