• HJC黄金城

    EPC Products Transducer & Data logger Strain Gauge Weldable AWM-8 Quarter bridge with 3-wire system
    产品中心
    AWM-8 Quarter bridge with 3-wire system

    Model:AWM-8

    Use:The AWM is usable up to 300℃ for both static and dynamic measurement.

    Standard:

    The AWM is usable up to 300℃ for both static and dynamic measurement. The backing material is available in Inconel 600 or SUS304 which should be selected according to the test specimen material.

    Main object material Metal
    Operational temperature -196 to +300℃
    Temperature compensation range RT to +300℃
    Bonding adhesive Spot welding (TML spot welder W-50R is required)
    Backing Inconel 600, SUS304
    Element Special alloy
    Strain limit 1% (10000 x 10-6 strain)
    Fatigue life at room temperature 1×106 (±1000×10-6 strain)